Stability Chamber vs Humidity Chamber vs BOD Incubator
Compare Aureole's Stability Chamber, Humidity Chamber and BOD Incubator by temperature and humidity range, accuracy and use.
Specifications compared
- Temperature range: Stability Chamber 20°C to 60°C; Humidity Chamber 20°C to 60°C; BOD Incubator 10°C to 60°C
- Humidity range: Stability Chamber 40% to 95% RH; Humidity Chamber 40% to 95% RH; BOD Incubator not specified (temperature only)
- Accuracy: Stability Chamber ± 0.3°C / ± 2.0% RH; Humidity Chamber ± 0.3°C / ± 2.0% RH; BOD Incubator ± 0.5°C
- Uniformity: Stability Chamber ± 1.0°C / ± 3.0% RH; Humidity Chamber ± 1.0°C / ± 3.0% RH; BOD Incubator ± 2.5°C
- 21 CFR Part 11 support: add-on option on all three
Which one do I need?
- Long-term pharmaceutical stability studies with controlled temperature and humidity: Stability Chamber
- Temperature and humidity testing across industries: Humidity Chamber
- Controlled temperature only, for example incubating cultures: BOD Incubator
- Room-sized storage, testing or incubation: Walk In Humidity Chamber or Walk In BOD Incubator
- Light exposure studies (ICH Q1B): Photostability Chamber; cold storage at 2°C to 8°C: Cold Chamber
Chamber comparison: quick answers
What is the difference between a stability chamber and a humidity chamber?
On Aureole's product pages both list 20°C to 60°C and 40% to 95% RH. The Stability Chamber is built around long-term stability studies of pharmaceutical products; the Humidity Chamber is described for temperature and humidity testing across several industries. Stability Chamber
Does a BOD incubator control humidity?
The BOD Incubator is specified for temperature only: 10°C to 60°C with ± 0.5°C accuracy. For controlled humidity (40% to 95% RH) choose a Stability Chamber or Humidity Chamber. BOD Incubator
Which Aureole chamber is listed for 25°C/60% RH and 30°C/75% RH conditions?
The Humidity Chamber is listed as suitable for 25°C & 60% RH, 30°C & 65% RH, 40°C & 75% RH and 30°C & 75% RH. Light exposure studies use the Photostability Chamber, designed in accordance with ICH Q1B. Humidity Chamber
Is 21 CFR Part 11 support available?
Yes, as an add-on option on all three. Aureole monitoring software supports Part 11 requirements through access controls, electronic signatures and audit trails; compliance of an installation also depends on how the customer validates and operates it. Monitoring software
Where are these chambers made and do you export?
They are made in Nashik, India, and supplied in India and to 15+ countries.